SECTION VIII STORMWATER RUNOFF CONTROL (SUBDIVISION REGS)
1.      The subdivider shall furnish projections of the increase of stormwater runoff created by the    proposed development from the 2-year, 10-year, and 100-year frequency, 24-hour duration type III        distribution storms, as computed in accordance with Technical Release #55, Urban Hydrology,
       Engineering Division, Soils Conservation Service, USDA, January, 1975, as amended or by use of  other methods conforming to sound engineering practice. Rational method shall not be used in    computing drainage flows in drainage basin areas in excess of one thousand (1,000) acres.

2.      Information to Be Submitted By Developer

       A.      All storm drainage calculation must be designed and certified by a registered Professional              Engineer.  The following date shall be submitted for review by the Public Works                                 Department or its designated agent:

                       1.      Topographic Contour Maps(s) showing drainage area(s).

                2.     Written description and computation including at least the following:

                        a.      Method used to calculate storm water runoff.
                               b.      Runoff characteristics of the property before and after development.
                               c.      Drainage calculations.
                               d.      Maximum velocity and quantity at point or points of discharge from the                                  system.
                               e.      Design calculations for all drainage piping and structures.
                               f.      For detention structures:

                                       (1)     Inflow and outflow hydrographs for detention area.
                                       (2)     Maximum storage volume.
                                       (3)     Design of spillway or other measures for the release of excess                                          flows beyond that of the design capacity of the structure.
                                       (4)     Flood routing of all runoff greater than the design capacity of                                                 the detention facility.
                                       (5)     Time which is required for the facility to drain completely.
                                       (6)     Materials used in construction of the facility.
                                       (7)      Methods employed to avoid clogging the discharge                                                       mechanism.
                                       (8)     Safety measures.
                                       (9)     Proposed landscaping and vegetative measures used to                                            stabilize slopes and bottom surfaces.

3.      No increase in peak flow from those storms referred to in 1. above shall be allowed unless      downstream increases are compatible with an overall flood plain management system.  The         following items should be considered in determining whether increased peak flows are compatible         with an overall flood plain management system:

       A.      The timing of peak flows from sub-watersheds

       B.      The increased duration of high flow rates

       C.      The stability of the downstream channels

       D.      The distance downstream that the peak discharges are increased.

4.      When stormwater detention structures are required, they shall be designed so that the peak runoff       after development shall not exceed nor be substantially less than the peak runoff prior to      development for each of the above flood events. The subdivider shall be responsible for         maintenance of the structure. The structures shall be designed and constructed in accordance
       with good engineering practice.  Basin(s) shall be designed for easy access for maintenance     purposes and be provided with safety measures as needed.



 